BIOMECHANICAL STUDY OF THE STABILITY OF OSTEOSYNTHESIS OF THE FRACTURE OF THE PROXIMAL HUMERUS BY THE DEVELOPED DEVICE IN COMPARISON WITH A STANDARD BONE LOCKING PLATE. COMPUTER MODELING BY THE FINITE ELEMENT METHOD

Authors

DOI:

https://doi.org/10.34689/hk40wr30

Keywords:

Proximal humerus fracture, computer modeling by finite elements, newly designed device, osteosynthesis, bone-plate models

Abstract

Introduction. Proximal humerus fractures (PHF) are the third most common fractures after fractures of the femoral neck 
and distal metaepiphysis of the radius. PHF are most often found in the elderly and old people. Despite the availability of a 
large number of surgical treatment methods, a large number of complications are still observed, such as secondary 
displacement, screw eruption and aseptic necrosis. In this study computer modeling was carried out to determine the 
biomechanical characteristics of osteosynthesis of a PHF with a new device, and the immediate results of the operation on a 
patient are given as a clinical example. 
Research objective. Comparative study using the finite element method of computer models of the humerus, which 
fixed by the developed device and a standard bone plate. 
Materials and methods. A new device for proximal humerus fractures fixing has been developed and manufactured. 
Based on a CT scan of the shoulder joint of a middle-aged man, a 3D model of the humerus was developed. On the 
humerus models was applied simulation of 500 N compression loads along the axis and axial sharing with 200, rotational 
loads with a force of 200 N. The results of biomechanical experiments obtained during computer modeling, the distribution 
points of the maximum von Mises stress, and the restoration of shoulder joint function in the early postoperative period were 
studied. 
Results. The results of computer modeling using the finite element method showed that the von Mises stress distribution 
was smaller in the humerus model fixed by the new device than in the model fixed by the standard plate. In the humerus 
model with the standard plate, the displacement of bone fragments was greater. The patient who underwent surgery had 
good recovery of the shoulder joint function, with a Constant Murley (Score) score of 85%. 
Conclusion. Osteosynthesis of the proximal humerus fracture by the new device increases fracture stability, prevents 
secondary displacement of bone fragments and promotes early restoration of movement in the shoulder joint.

Author Biographies

  • Arman Mussabekov

    assistant of the Department of Traumatology of Semey Medical University, Semey, Republic of 
    Kazakhstan.

  • Yersin Zhunussov

    Professor of the International Science Center of Traumatology and Orthopedics. Almaty. Republic of
    Kazakhstan; E-mail: ersin-surgery@mail.ru; phon: 8(777)6238923; https://orcid.org/0000-0002-1182-5257.

  • Aidos Tlemisov

    Director of the “Center for Habilitation and Rehabilitation of Persons with Disabilities of Abai Region”,
    Department of Employment Coordination and Social Programs of the Abai Region, Semey, Republic of Kazakhstan, phone:
     7 775 791 36 56, e-mail: aidos_8668@mail.ru, https://orci

  • Sabina Aubakirova

    Ассистент кафедры травматологии и детской хирургии, НАО «Медицинский
    университет Семей», г. Семей, Республика Казахстан

References

Mussabekov A.S., Zhunussov Ye.T., Zhanaspayev M.A., Tlemisov A.S., Aubakirova S.K., Prokazyuk A.A. Biomechanical study of the stability of osteosynthesis of the fracture of the proximal humerus by the developed device in comparison with a standard bone locking plate. Computer modeling by the finite element method // Nauka i Zdravookhranenie [Science & Healthcare]. 2024. Vol.26 (6), pp. 81-87. doi 10.34689/SH.2024.26.6.010

Мусабеков А.С., Жунусов Е.Т., Жанаспаев М.А., Тлемисов А.С., Аубакирова С.К., Проказюк А.А. Биомеханическое исследование стабильности остеосинтеза перелома проксимального отдела плечевой кости разработанным устройством в сравнении со стандартной накостной блокируемой пластиной. Компьютерное моделирование методом конечных элементов // Наука и Здравоохранение. 2024. Т.26 (6). С. 81-87. doi 10.34689/SH.2024.26.6.010

Мусабеков А.С., Жунусов Е.Т., Жанаспаев М.А., Тлемисов А.С., Аубакирова С.К., Проказюк А.А. Иық сүйегінің проксимальды бөлігінің сынығын әзірленген құрылғымен және стандартты сүйекүстілік құлыптаушы пластинамен остеосинтезінің тұрақтылығын салыстырмалы түрде биомеханикалық зерттеуі. Соңғы элементтер әдісімен компьютерлік модельдеу // Ғылым және Денсаулық сақтау. 2024. Т.26 (6). Б. 81-87. doi 10.34689/SH.2024.26.6.010

Downloads

Published

2025-11-07

Issue

Section

Статьи

Categories

How to Cite

BIOMECHANICAL STUDY OF THE STABILITY OF OSTEOSYNTHESIS OF THE FRACTURE OF THE PROXIMAL HUMERUS BY THE DEVELOPED DEVICE IN COMPARISON WITH A STANDARD BONE LOCKING PLATE. COMPUTER MODELING BY THE FINITE ELEMENT METHOD. (2025). Рецензируемый медицинский научно-практический журнал «Наука и здравоохранение», 26(6), 81-87. https://doi.org/10.34689/hk40wr30

Similar Articles

1-10 of 47

You may also start an advanced similarity search for this article.